CTWell2S

Christian Truee
Deep Well Drilling Supporting Services

Sampling of samples from deep wells


Fluid – samples

  • Liquid Samples in pressureless condition
    Volume: upto 4.000 cm³ per RIH
    sample transfer in glas bottles or containers delivered by customer
  • Fluid Samples in pressureless condition
    Volume: 600 cm³ or 1.000 cm³ per RIH
    working conditions sampler:
    working pressure: max. 700 bar
    working temperature: max. 150°C
    sample transfer in glas bottles or containers delivered by customer
    take over generally separate for gas and liquid
  • Fluid samples in situ
    Volume: 600 cm³ per RIH or sampler
    Working conditions sampler:
    working pressure: max. 1.000 bar
    working temperature: max. 180°C
    Sample transfer in special transport bottles, the provision are part of the scope of services.
    The transfer of the sample is carried out under sampling pressure conditions. Therefore the samples are suitable for PVT analysis.
    Transport bottles are approved for transport in airplanes.

Solid Samples

  • Sand pump bailers are usually used to take solid samples. The size can be selected according to the Borehole situation as well as the subsurface installation.