Liquid Samples in pressureless condition
Volume: upto 4.000 cm³ per RIH
sample transfer in glas bottles or containers delivered by customer
Fluid Samples in pressureless condition
Volume: 600 cm³ or 1.000 cm³ per RIH
working conditions sampler:
working pressure: max. 700 bar
working temperature: max. 150°C
sample transfer in glas bottles or containers delivered by customer
take over generally separate for gas and liquid
Fluid samples in situ
Volume: 600 cm³ per RIH or sampler
Working conditions sampler:
working pressure: max. 1.000 bar
working temperature: max. 180°C
Sample transfer in special transport bottles, the provision are part of the scope of services.
The transfer of the sample is carried out under sampling pressure conditions. Therefore the samples are suitable for PVT analysis.
Transport bottles are approved for transport in airplanes.
Solid Samples
Sand pump bailers are usually used to take solid samples. The size can be selected according to the Borehole situation as well as the subsurface installation.